GC/MS-MS Applications




Click To View
 
Pesticide Determination at 0.01 mg/kg
A huge number of different pesticides are being regularly applied in the agricultural industry, including insecticides, fungicides, herbicides, and growth regulators. The inherent superior selectivity of GC/MS-MS allows interference-free quantification and positive confirmation of various pesticides in a single analytical run, even with coeluting compounds. This application note shows the capabilities of the CHROMTECH EVOLUTION MS/MS triple quadrupole mass spectrometer utilyzing MRM Technique for multi-pesticides residue analysis.



Click To View
 
Analysis of PCBs in Fish Tissue
Low level PCB contamination can be monitored by analyzing fish tissue. Congener-specific analysis of the PCBs in fish tissues is often performed by GC-ECD or GC-MS. Unfortunately, both techniques suffer significant limitations due to the often huge amount of matrix compounds found in the sample extracts. This application note describes the successful use of the CHROMTECH EVOLUTION Triple Quadrupole GC-MS/MS system for the analysis of PCB in fish tissue. The selectivity of Evolution GC-MS/MS is used to increase sensitivity and minimize matrix effects while greatly reducing the possibility of false positives.



Click To View
 
Herbicide Residues
This short application describes the use of the Chromtech Evolution GC/MS-MS in combination with a quick sample extraction procedure in the analysis of herbicide residues. Demonstrating GC/MS-MS is extremely effective for overcoming highly suppressing matrix effects that often plague single quadrupole instruments.



Click To View
 
Triple Quadrupole MS: MRM the Method of Choice for Complex Samples
Improper and/or illicit use of pesticides on agricultural produce can cause unacceptable high levels of their residues in produce intended for human consumption. Worldwide there are over 800 compounds currently in use, Food safety concerns are increasing among consumers worldwide. This application note compares the results of SIM versus MRM using the CHROMTECH EVOLUTION MS/MS triple quadrupole mass spectrometer for Tebuconazol in a real sample extract.



Click To View
 
Analysis of Pyrethoids - A Case Study during Installation
This note summarizes some results obtained during installation of the Evolution-GCMS/MS. In the customers lab we had the chance to show again the potential of GC/MS-MS for a quick and unambigous detection of trace compounds.




Click To View
 
Determination of Cannabis Metabolite in Hair - (THC-COOH)
Utilizing the Chromtech Evolution GC/MS-MS for determination of the metabolite THC-COOH from a human hair sample for the detection of cannabis use within the last 30 days of its consumption. The CHROMSYS Evolution is controlled via Chemstation. An additional window is added within Chemstation for the Evo SIM/Scan parameters in which the user can choose the parent/daughter ions as well as the collision energy for each compound to be analyzed.



Click To View
 
Evolution-GC/MS-MS: Analysis of Doping Confirmation Compounds
Derivatized (TMS) urine samples were used to check the sensitivity and linearity for some commonly known substances in the field of doping analysis. We adjusted the GC/MS-MS parameters as close as possible to the values that are used at this customerĀ“s lab. and checked the performance of this upgraded 6890N/5973 Evolution Triple Quad system.